When running CAU preview Updates on my Windows 2016 Cluster it fails with the below error
In the applicable updates to each node in this cluster, the following problems were encountered.
The Microsoft.WindowsUpdatePlugin plug-in reported a failure while attempting to scan for applicable updates on node "<g class="gr_ gr_38 gr-alert gr_spell gr_inline_cards gr_run_anim ContextualSpelling ins-del multiReplace" data-gr-id="38" id="38">Netbios</g> Name". Additional information reported by the plug-in: (ClusterUpdateException) There was a failure in a Common Information Model (CIM) operation, that is, an operation performed by software that Cluster-Aware Updating depends on. The computer was "<g class="gr_ gr_58 gr-alert gr_spell gr_inline_cards gr_run_anim ContextualSpelling ins-del multiReplace" data-gr-id="58" id="58">Netbios</g> Name", and the operation was "ScanUpdates[Info,CauNodeWCD[Netbios Name]]". The failure was: The service cannot be started, either because it is disabled or because it has no enabled devices associated with it ==> (CimException) The service cannot be started, either because it is disabled or because it has no enabled devices associated with it. HRESULT 0x80070422
Tried Reconfiguring the CAU,
Ran the below
Run an Administrative Command Prompt
Change to the C:\WINDOWS\SYSTEM32\WBEM folder
Run the command MOFCOMP CAUWMIv2.MOF
Still same error. The Cluster has gone through a Rolling Update from Windows 2012 to Windows 2016. Had 3 Node 2012 R2 running with CAU previously. Removed CAU and added 3 New 2016 Servers to the Cluster and then removed 3 Old 2012 Nodes. Upgraded the Cluster Functional level and then configuration version also updated. Once all these Steps completed <g class="gr_ gr_80 gr-alert gr_spell gr_inline_cards gr_run_anim ContextualSpelling ins-del multiReplace" data-gr-id="80" id="80">re added</g> the CAU and still am receiving the above error
Can anyone please help me to fix this as am stuck
In the applicable updates to each node in this cluster, the following problems were encountered.
The Microsoft.WindowsUpdatePlugin plug-in reported a failure while attempting to scan for applicable updates on node "<g class="gr_ gr_38 gr-alert gr_spell gr_inline_cards gr_run_anim ContextualSpelling ins-del multiReplace" data-gr-id="38" id="38">Netbios</g> Name". Additional information reported by the plug-in: (ClusterUpdateException) There was a failure in a Common Information Model (CIM) operation, that is, an operation performed by software that Cluster-Aware Updating depends on. The computer was "<g class="gr_ gr_58 gr-alert gr_spell gr_inline_cards gr_run_anim ContextualSpelling ins-del multiReplace" data-gr-id="58" id="58">Netbios</g> Name", and the operation was "ScanUpdates[Info,CauNodeWCD[Netbios Name]]". The failure was: The service cannot be started, either because it is disabled or because it has no enabled devices associated with it ==> (CimException) The service cannot be started, either because it is disabled or because it has no enabled devices associated with it. HRESULT 0x80070422
Tried Reconfiguring the CAU,
Ran the below
Run an Administrative Command Prompt
Change to the C:\WINDOWS\SYSTEM32\WBEM folder
Run the command MOFCOMP CAUWMIv2.MOF
Still same error. The Cluster has gone through a Rolling Update from Windows 2012 to Windows 2016. Had 3 Node 2012 R2 running with CAU previously. Removed CAU and added 3 New 2016 Servers to the Cluster and then removed 3 Old 2012 Nodes. Upgraded the Cluster Functional level and then configuration version also updated. Once all these Steps completed <g class="gr_ gr_80 gr-alert gr_spell gr_inline_cards gr_run_anim ContextualSpelling ins-del multiReplace" data-gr-id="80" id="80">re added</g> the CAU and still am receiving the above error
Can anyone please help me to fix this as am stuck